Parr-instrument 6755 Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Parr-instrument 6755. Parr Instrument 6755 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Operating Instruction Manual

593M6755Solution CalorimeterOperating Instruction ManualFor models produced after November 2010

Strany 2 - Table of Contents

3OperationParr Instrument Company8CHAPTER 3OperationMenu SystemAll confi gurations and operations are handled by a menu-driven system operated from the

Strany 3 - PREFACE

Operation67553www.parrinst.com9Note: Changes to the program are made by use of the menu structure. Any of these items can be individually entered at

Strany 4 - Explanation of Symbols

3OperationParr Instrument Company10Sample SizeThe rotating sample cell will hold up to 20 ml of liquid sample or a solid sample weighing up to one gra

Strany 5

Operation67553www.parrinst.com11Emptying the CalorimeterStop the calorimeter motor, raise the cover carefully and wipe any excess liquid from the part

Strany 6 - Installation

4Menu DescriptionsParr Instrument Company12CHAPTER 4Menu DescriptionsNote: Keys which make global changes to the setup of the calorimeter contain a Y

Strany 7

Menu Descriptions67554www.parrinst.com13Temperature Plot Setup MenuEnable Bucket: Toggles ON/OFF.Bucket Autoscale: Toggles ON/OFF.Enable Jacket: To

Strany 8 - Quick Start

4Menu DescriptionsParr Instrument Company14Operating Controls MenuMethod of Operation: Offers an operating mode of either combustion or solution. In

Strany 9 - Notes

Menu Descriptions67554www.parrinst.com15Date & Time SettingsDate: Displays current date and accesses the sub-menu on which the date is set (YY/MM

Strany 10 - Operation

4Menu DescriptionsParr Instrument Company16Data Entry Controls Menu Auto Sample ID Controls: Accesses sub-menu for controlling the automatic assignme

Strany 11

Menu Descriptions67554www.parrinst.com17Communication Controls MenuAccesses sub-menus which set the communications protocols for the printer and balan

Strany 12

Table of ContentsPreface Scope — 1Related Instructions — 1Customer Service — 1Explanation of Symbols — 2Safety Information — 3Intended Usage — 3Genera

Strany 13

4Menu DescriptionsParr Instrument Company18Balance Port Settings » Number of Data Bits. Standard options for data bits. Toggles between 7 and 8. » Par

Strany 14 - Menu Descriptions

Menu Descriptions67554www.parrinst.com19File Management MenuFile Management MenuRun Data File Manager: This key activates the File Manager. The File

Strany 15

4Menu DescriptionsParr Instrument Company20Diagnostics MenuProvides the user with the means to test many of the components and subsystems of the Calor

Strany 16

Menu Descriptions67554www.parrinst.com21Data Log Format: Toggles between Text Format and Data Format (csv). Data is either logged with the supportin

Strany 17

5CalculationsParr Instrument Company22CHAPTER 5CalculationsStandardizationA sample of tris (hydroxymethyl) aminomethane, commonly called TRIS, is furn

Strany 18

Calculations67555www.parrinst.com23Calculating the Energy ChangeThe energy change, Q, measured in this calorimeter is calculated by multiplying the ne

Strany 19

5CalculationsParr Instrument Company24Figure 3Exothermic ReactionExample - Exothermic ReactionProblem: Determine the change in enthalpy for solid sodi

Strany 20

Calculations67555www.parrinst.com25Figure 4Endothermic ReactionExample - Endothermic ReactionProblem: Determine the heat of solution of solid potassiu

Strany 21

6ReportsParr Instrument Company26CHAPTER 6Reports The 6772 Calorimetric Thermom-eter can transmit its stored test data in either of two ways. The Au

Strany 22

Memory Management67557www.parrinst.com27CHAPTER 7Memory Management The 6772 Calorimetric Thermometer will hold data for 1000 tests in its memory. Th

Strany 23

Preface6755www.parrinst.com1PREFACE ScopeThis manual contains instructions for installing and operating the Parr 6755 Solution Calorimeter. For ease

Strany 24 - Calculations

8Accessory ConnectionsParr Instrument Company28CHAPTER 8Accessory ConnectionsCommunication ConnectionThere is a USB connection on the rear of the 6772

Strany 25

Accessory Connections67558www.parrinst.com29Bar Code PortThe use of barcodes in the laboratory has become a highly accurate, rapid and inexpensive way

Strany 26

8Accessory ConnectionsParr Instrument Company30The following screenshot illustrates the contents of the Calorimetric Thermometer data directory as pre

Strany 27

Accessory Connections67558www.parrinst.com31The Calorimetric Thermometer offers a web server service. Test reports can be viewed with a web browser us

Strany 28 - CHAPTER 6

8Accessory ConnectionsParr Instrument Company32Clicking on the Confi g tab displays some of the confi guration options available in the 6772. Changes m

Strany 29 - Memory Management

Accessory Connections67558www.parrinst.com33Clicking on the Run Data tab displays a list of reports currently in the instrument memory. Clicking on a

Strany 30 - Accessory Connections

8Accessory ConnectionsParr Instrument Company34 Clicking on System Info will bring up the Software and Hardware Info screen from the 6772.

Strany 31

Accessory Connections67558www.parrinst.com35Clicking on the LCD Snapshot Page will bring up an image of the current display on the 6772. Note that th

Strany 32

8Accessory ConnectionsParr Instrument Company36Clicking on Documentation will provide links to the manual and other helpful documents. Note: a conne

Strany 33

Accessory Connections67558www.parrinst.com37Remote Operation (Optional)The 6772 can be operated remotely via PC over a network with the purchase of th

Strany 34

PrefaceParr Instrument Company2Explanation of SymbolsI On PositionO Off Position~ Alternating CurrentThis CAUTION symbol may be present on the Product

Strany 35

9MaintenanceParr Instrument Company38CHAPTER 9MaintenanceExamine the rotating cell periodically for leaks by closing the cell and submerging the empty

Strany 36

Troubleshooting675510www.parrinst.com39CHAPTER 10TroubleshootingError ListThe calorimeter will run a number of diagnostic checks upon itself and will

Strany 37

11Technical ServiceParr Instrument Company40CHAPTER 11Technical ServiceContact UsTechnical Service DepartmentShould you need assistance in the operati

Strany 38

Parts List675512www.parrinst.com41CHAPTER 12Parts ListsParts for the 6755 Solution CalorimeterPart Number DescriptionA338CEB Stirrer Drive Motor Assem

Strany 39

13DrawingsParr Instrument Company42CHAPTER 13DrawingsExternal Parts View of 6755 Solution Calorimeter

Strany 40 - Maintenance

Drawings675513www.parrinst.com43Internal Parts View of 6755 Solution Calorimeter

Strany 41 - Troubleshooting

13DrawingsParr Instrument Company44USB PORTJ8J10P6P8J1A2165ETRANSITIONA1821EJ19J2A2164E BACKLIGHT CONTROL CABLE ASSYBOARD TOPIN #1SPEAKERJ5J6PIN #1LCD

Strany 42 - Technical Service

Drawings675513www.parrinst.com45Internal Parts View of 6772 Calorimetric ThermometerASSY2X TN1140HL2X 379E2BRACKET, CAPACITOR911E FILTERINTERFERENCE,

Strany 43 - Parts Lists

13DrawingsParr Instrument Company46Internal Parts View of 6772 Calorimetric ThermometerNote: 1262DD Capacitor Bracket and 897E Capacitor not shown for

Strany 44 - Drawings

Drawings675513www.parrinst.com47(SEE NOTE)DATA LABEL95FBACK VIEW2X SA1332RP066-32 X 3/8 RHMS PHILLIPS6-32 X 3/8 RHMS PHILLIPSBACK PANEL (REF)327C2SA13

Strany 45

Preface6755www.parrinst.com3Safety InformationTo avoid electrical shock, always:1. Use a properly grounded electrical outlet of correct voltage and c

Strany 46

14Default SettingsParr Instrument Company48Calorimeter OperationStirrer OFFOperating ControlsMethod of Operation SolutionLCD Backlight Timeout(s) 120

Strany 48

Revision 07/08/13

Strany 49

1InstallationParr Instrument Company4CHAPTER 1InstallationThe 6755 Solution Calorimeter requires approximately 4 square feet of work space on a sturdy

Strany 50 - Default Settings

Installation67551www.parrinst.com5Figure 1NOTE: CONNECT UNTERMINATED 493E WITH 328HC BRACKET TO THE MOTOR OUTPUT RECEPTACLE SECURING IT USING THE SA1

Strany 51

2Quick StartParr Instrument Company6CHAPTER 2Quick Start Before starting to use the calorimeter for the fi rst time, it is recommended that the user p

Strany 52 - Revision 07/08/13

www.parrinst.com7Notes 6755

Komentáře k této Příručce