Parr-instrument 6200 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Parr-instrument 6200. Parr Instrument 6200 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 94
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Operating Instruction Manual
No. 442M
9
6200
Oxygen Bomb Calorimete
r
Zobrazit stránku 0
1 2 3 4 5 6 ... 93 94

Shrnutí obsahu

Strany 1 - Oxygen Bomb Calorimete

Operating Instruction Manual No. 442M9 6200Oxygen Bomb Calorimeter

Strany 2

116200Calorimeter Operating Instruction ManualOverview The 6200 Calorimeter has been designed to provide the user with: • A traditional design ca

Strany 3

12 6200Calorimeter Operating Instruction ManualFull Micro-processor Based Process Control Full Micro-processor Based Data Acquisition and Handling

Strany 4

136200Calorimeter Operating Instruction ManualFilling the Jacket ReservoirPowerConnectionJacket Cooling Water Connection The 6200 Calorimeter is co

Strany 5

14 6200Calorimeter Operating Instruction ManualJacket Cooling Water Connection Continued Oxygen Filling Connection Printer and Balance Connections 2

Strany 6

156200Calorimeter Operating Instruction ManualRetightening Swagelok Tube Fittings When Swagelok Tube Fittings are used, the instructions for ins

Strany 7

16 6200Calorimeter Operating Instruction Manual Figure 2-1 6200 Calorimeter Back Panel 2-42

Strany 8

176200Calorimeter Operating Instruction Manual2 Line 1 & 2 – Maximum length of 10 feet -¼” OD, Polyurethane (Part Number HJ0025TB035) Line 3

Strany 9

18 6200Calorimeter Operating Instruction Manual Open Loop Configurations Figure 2-4 Figure 2-5 2-6 2

Strany 10 - 6200Calorimeter O

196200Calorimeter Operating Instruction ManualStandardizing the Calorimeter The calorimeter must be accurately standardized prior to actually perfo

Strany 11

20 6200Calorimeter Operating Instruction Manual2This page intentionally left blank. 2-8

Strany 12

36200Calorimeter Operating Instruction ManualPreface I Scope...

Strany 13

216200Calorimeter Operating Instruction ManualControl Keys All calorimeter configurations and operations are handled by a menu-driven system operat

Strany 14

22 6200Calorimeter Operating Instruction Manual3 This page intentionally left blank.3-2

Strany 15

236200Calorimeter Operating Instruction Manual The program in the 6200 Calorimeter can be extensively modified to tailor the unit to a wide variety

Strany 16

24 6200Calorimeter Operating Instruction ManualRevising Default Settings The default parameters of the 6200 Calorimeter can be changed to guarante

Strany 17

256200Calorimeter Operating Instruction ManualFigure 4- 1 6200 Factory Default Settings Calorimeter Operation Operating Mode Determination Bomb

Strany 18

26 6200Calorimeter Operating Instruction Manual4 Data Entry Controls Prompt for Bomb ID ON Weight Entry Mode Touch Screen Acid Entry Mode Touch

Strany 19

276200Calorimeter Operating Instruction ManualOperating the Filling Connection Detailed Instructions for preparing the sample and charging the 1108

Strany 20

28 6200Calorimeter Operating Instruction ManualOperating the Calorimeter All operations required to standardize the 6200 Calorimeter, or test an un

Strany 21

296200Calorimeter Operating Instruction Manual4. Set the bucket in the calorimeter. Attach the lifting handle (421A) to the two holes in the side

Strany 22

30 6200Calorimeter Operating Instruction Manual10. Remove all unburned pieces of fuse wire from the bomb electrodes; straighten them and measure the

Strany 23

4 6200Calorimeter Operating Instruction Manual Operating Instructions 5-1 Operating the 1108 Oxygen Bomb...

Strany 24

316200Calorimeter Operating Instruction Manual Particle Size and Moisture Content. Solid samples burn best in an oxygen bomb when reduced to 60 m

Strany 25

32 6200Calorimeter Operating Instruction ManualCombustion CapsulesCoarse Samples Non-volatile samples to be tested in Parr oxygen bombs are weighed

Strany 26

336200Calorimeter Operating Instruction ManualCorrosive Samples 5 The 1108 Oxygen Bomb is made of a corrosion resistant alloy designed to withstan

Strany 27

34 6200Calorimeter Operating Instruction Manual Use the following procedure when filling and handling any of these tape-sealed sample holders: •

Strany 28

356200Calorimeter Operating Instruction Manual Final reports for each test can be obtained whenever the operator is prepared to enter any required

Strany 29

36 6200Calorimeter Operating Instruction Manual This page intentionally left blank.6 6-2

Strany 30

376200Calorimeter Operating Instruction ManualReportOption SelectionReport Generation The 6200 Calorimeter can transmit its stored test data in eit

Strany 31

38 6200Calorimeter Operating Instruction Manual The displayed files can be sorted by sample ID number, by type, by status or by date of test by sim

Strany 32

396200Calorimeter Operating Instruction ManualClearing Memory The 6200 Calorimeter will hold data for 1000 tests in its memory. These tests may be

Strany 33

40 6200Calorimeter Operating Instruction Manual This page intentionally left blank.88-2

Strany 34

56200Calorimeter Operating Instruction ManualAppendix B – Calculations B-1 Calculating the Heat of Combustion...

Strany 35

416200Calorimeter Operating Instruction Manual Under normal usage the 1108 Parr Oxygen Bomb will give long service if handled with reasonable care.

Strany 36

42 6200Calorimeter Operating Instruction ManualThe replacement of protective fuses for the 6200 Calorimeter should be performed by qualified personn

Strany 37

436200Calorimeter Operating Instruction Manual A / D Initialization Failed. Shortly after power is applied to the calorimeter controller and the op

Strany 38

44 6200Calorimeter Operating Instruction Manual This page intentionally left blank.99-4

Strany 39

456200Calorimeter Operating Instruction Manual The settings and controls are organized into nine main sections or pages which comprise the Main Men

Strany 40

46 6200Calorimeter Operating Instruction Manual Setup. Press this key to access the Temperature Plot Setup Menu, which has many keys tha

Strany 41

476200Calorimeter Operating Instruction Manual Time Units. Toggles between minutes and seconds. Bucket Plot Color. Toggles between: • Red • Green •

Strany 42

48 6200Calorimeter Operating Instruction ManualOperating Controls Menu Method of Operation. Offers an operating mode of either dynamic

Strany 43

496200Calorimeter Operating Instruction ManualProgram Information and Control Menu Calibrate Touchscreen. This key prompts the user to touch the sc

Strany 44

50 6200Calorimeter Operating Instruction ManualProgram Information and Control MenuContinuedCalibration Data and Controls Menu Save User Default Set

Strany 45

6 6200Calorimeter Operating Instruction Manual Figures 2-1 6200 Calorimeter Back Panel ...

Strany 46

516200Calorimeter Operating Instruction ManualCalibration and Data Controls Menu Continued EE Max Std Deviation. Displays the maximum relative stan

Strany 47

52 6200Calorimeter Operating Instruction ManualThermo-chemical Corrections MenuPrint Standardization Runs. Will print all of the tests that have bee

Strany 48

536200Calorimeter Operating Instruction ManualCalculation Factors. Accesses sub-menu, Calculation Factors which sets a number of options for the way

Strany 49

54 6200Calorimeter Operating Instruction ManualData Entry Controls Menu Prompt for Bomb ID. In the ON position the controller will pro

Strany 50

556200Calorimeter Operating Instruction ManualAuto Preweigh ID Controls. Accesses sub-menu, used to automatically assign Sample ID numbers when a se

Strany 51

56 6200Calorimeter Operating Instruction Manual Communication Controls. Accesses sub-menus which set the communications protocols for t

Strany 52

576200Calorimeter Operating Instruction ManualBalance Port (RS232). Accesses sub-menu, Balance Port Communications. Balance Type. This key toggl

Strany 53

58 6200Calorimeter Operating Instruction ManualFile Management MenuAPPENDIX A Run Data File Manager - This key activates the File Manager. The File

Strany 54

596200Calorimeter Operating Instruction ManualDiagnostics Menu APPENDIX A Allows the user to test many of the components and subsystems of the c

Strany 55

60 6200Calorimeter Operating Instruction Manual This page intentionally left blank.APPENDIX A8-2

Strany 56

76200Calorimeter Operating Instruction ManualScope This manual contains instructions for installing and operating the Parr 6200 Calorimeter. For ea

Strany 57

616200Calorimeter Operating Instruction ManualCalculating the Heat of CombustionGeneral Calculations The 6200 Calorimeter will automatically make a

Strany 58

62 6200Calorimeter Operating Instruction ManualThermochemical Corrections Nitric Acid Correction. In the high pressure oxygen environment within

Strany 59

636200Calorimeter Operating Instruction Manual Current ASTM, ISO, and British Standard Methods differ on their treatment of the nitric and sulfuric

Strany 60

64 6200Calorimeter Operating Instruction Manual• Total acid is the amount of base required to titrate the bomb washings (milliliters). • Nitric ac

Strany 61

656200Calorimeter Operating Instruction ManualAcid and Sulfur CorrectionsContinued Users may find it convenient to enter a fixed value for the acid

Strany 62

66 6200Calorimeter Operating Instruction Manual In the ASTM treatment, the correction for acid formation assumes that all the acid titrated is nitr

Strany 63

676200Calorimeter Operating Instruction Manualm Spiking SamplesConversion to Other Moisture BasesConversion to Net Heat of Combustion It is someti

Strany 64

68 6200Calorimeter Operating Instruction Manual This page intentionally left blank.APPENDIX BB-8

Strany 65

696200Calorimeter Operating Instruction ManualStandard Materials The Energy Equivalent Factor. The term “standardization”, as used here, denotes

Strany 66

70 6200Calorimeter Operating Instruction Manual The 6200 Calorimeter includes a provision for calculating and using a mean energy equivalent for ea

Strany 67

8 6200Calorimeter Operating Instruction ManualPREFACE Explanation of Symbols I On position O Off position ~ Alternating Current (AC) This CAUTION

Strany 68

716200Calorimeter Operating Instruction ManualPrinter Port Balance Port RS232C Connections The 6200 Calorimeter is also equipped with an RS232C port

Strany 69

72 6200Calorimeter Operating Instruction ManualSartoriousBalanceInterface Field Length polarity 1 space 1 data 8 space 1 stability 2 CR 1 LF 1 T

Strany 70

736200Calorimeter Operating Instruction ManualField Length data 9 CR 1 The data field should consist of 9 numeric characters (0 through 9, +, - a

Strany 71

74 6200Calorimeter Operating Instruction Manual Table D-2 6200 Calorimeter Run Data Template Field Desc

Strany 72

756200Calorimeter Operating Instruction Manual Calorimeter test data can be transferred to an Ethernet network connected computer using the FTP File

Strany 73

76 6200Calorimeter Operating Instruction Manual The following screenshot illustrates the contents of the calorimeter data directory as presented by

Strany 74

776200Calorimeter Operating Instruction Manual The calorimeter offers a web server service. Test reports can be viewed with a web browser using a UR

Strany 75

78 6200Calorimeter Operating Instruction Manual Clicking on the Sample Data tab displays a list of reports currently in the instrument memory.

Strany 76

796200Calorimeter Operating Instruction Manual Clicking on any given report will provide a display as follows.

Strany 77

80 6200Calorimeter Operating Instruction ManualBar Code PortNetwork Data Devices The use of barcodes in the laboratory has become a highly accurat

Strany 78

96200Calorimeter Operating Instruction ManualSafety Information To avoid electrical shock, always: 1. Use a properly grounded electrical outlet of

Strany 79

816200Calorimeter Operating Instruction Manual Should you need assistance in the operation or service of your instrument, please contact the Techni

Strany 80

82 6200Calorimeter Operating Instruction Manual This page intentionally left blank.APPENDIX EE-2

Strany 81

836200Calorimeter Operating Instruction Manual APPENDIX F 6200 CALORIMETER PARTS LIST Principal Asse

Strany 82

84 6200Calorimeter Operating Instruction ManualParts List for Temperature Control Assembly Item Description 1281DD 1417E 538VB 252HWHJ 280HWHJ A12

Strany 83

856200Calorimeter Operating Instruction ManualParts List for 6200 Stirrer Motor and Drive Item Description 1285DD 1241DD2 1242DD A1268DD Mount, Mot

Strany 84

86 6200Calorimeter Operating Instruction Manual Figure F-1 6200 Oxygen Bomb Calorimeter Cutaway Front F-4A

Strany 85

876200Calorimeter Operating Instruction Manual Figure F-2 6200 Oxygen Bomb Calorimeter Cutaway Rear F-5 A

Strany 86

88 6200Calorimeter Operating Instruction Manual F-6Figure F-3 A1279DD Control Schematic APPENDIX F

Strany 87

896200Calorimeter Operating Instruction Manual F-7 Figure F-4 Oxygen Solenoid Assembly & Fittings A

Strany 88

90 6200Calorimeter Operating Instruction Manual F-8Figure F-5 Water Tank Assembly APPENDIX F

Strany 89

10 6200Calorimeter Operating Instruction Manual These steps are offered to help the user become familiar with, install, operate and develop the full

Strany 90

916200Calorimeter Operating Instruction Manual F-9 Figure F-6 A1311DD Circulating Pump Assembly with Fittings APPENDIX F

Strany 91

92 6200Calorimeter Operating Instruction ManualF-10Figure F-7 Temperature Control Assembly with Fittings APPENDIX F

Strany 92

936200Calorimeter Operating Instruction ManualAPPENDIX F Figure F-8 A1284DD2 Stirrer Hub Assembly F-11

Strany 93

94 6200Calorimeter Operating Instruction Manual APPENDIX FF-12 Figure F-9 Stirrer Motor Assembly F-12

Strany 94 - Revision 01/29/10

Revision 01/29/10 PARR INSTRUMENT COMPANY 211 Fifty - Third Street Moline, Illinois 61265 USA 309 / 762-7716 800 / 872-7720 Fax 309 / 7